Commission Directive 2004/33/EC of 22 March 2004 implementing Directive 2002/98/EC of the European Parliament and of the Council as regards certain technical requirements for blood and blood components (Text with EEA relevance)
Annex VANNEX V
In force · version of Jan 9, 2015
QUALITY AND SAFETY REQUIREMENTS FOR BLOOD AND BLOOD COMPONENTS
(as referred to in Article 6)
1.THE BLOOD COMPONENTS
1.Red cell preparations
The components listed in points 1.1 to 1.8 may be further processed within blood establishments and must be labelled accordingly
1.1
Red cells
1.2
Red cells, buffy coat removed
1.3
Red cells, leucocyte-depleted
1.4
Red cells, in additive solution
1.5
Red cells, buffy coat removed, in additive solution
1.6
Red cells, leucocyte-depleted, in additive solution
1.7
Red cells, apheresis
1.8
Whole blood
2.Platelet preparations
The components listed in points 2.1 to 2.6 may be further processed within blood establishments and must be labelled accordingly
2.1
Platelets, apheresis
2.2
Platelets, apheresis, leucocyte-depleted
2.3
Platelets, recovered, pooled
2.4
Platelets, recovered, pooled, leucocyte-depleted
2.5
Platelets, recovered, single unit
2.6
Platelets, recovered, single unit, leucocyte-depleted
3.Plasma preparations
The components listed in 3.1 to 3.3 may be further processed within blood establishments and must be labelled accordingly.
3.1
Fresh-frozen plasma
3.2
Fresh-frozen plasma, cryoprecipitate-depleted
3.3
Cryoprecipitate
4.
Granulocytes, apheresis
5.New components
Quality and safety requirements for new blood components must be regulated by the competent national authority. Such new components must be notified to the European Commission with a view to Community action
2.QUALITY CONTROL REQUIREMENTS FOR BLOOD AND BLOOD COMPONENTS
2.1.
Blood and blood components must comply with the following technical quality measurements and meet the acceptable results.
2.2.
Appropriate bacteriological control of the collection and manufacturing process must be performed.
2.3.
Member States must take all necessary measures to ensure that all imports of blood and blood components from third countries, including those used as starting material/raw material for the manufacture of medicinal products derived from human blood or human plasma, shall meet equivalent standards of quality and safety to the ones laid down in this Directive.
2.4.
For autologous donations, the measures marked with an asterisk (*) are recommendations only.
Component
Quality measurements required
The required frequency of sampling for all measurements shall be determined using statistical process control
Acceptable results for quality measurements
Red cells
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 45 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, buffy coat removed
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 43 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40 g per unit
Leucocyte content
Less than 1 × 10 6 per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 45 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, buffy coat removed, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 43 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, leucocyte-depleted, in additive solution
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40 g per unit
Leucocyte content
Less than 1 × 10 6 per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Red cells, apheresis
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
Haemoglobin (*)
Not less than 40 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Whole blood
Volume
Valid for storage characteristics to maintain product within specifications for haemoglobin and haemolysis
450 ml +/- 50ml
For paediatric autologous whole blood collections — not to exceed 10,5 ml per kg body weight
Haemoglobin (*)
Not less than 45 g per unit
Haemolysis
Less than 0,8 % of red cell mass at the end of the shelf life
Platelets, apheresis
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single donation are permitted within limits that comply with validated preparation and preservation conditions
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Platelets, apheresis, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single donation are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 1 × 10 6 per unit
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Platelets, recovered, pooled
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 0,2 × 10 9 per single unit (platelet-rich plasma method)
Less than 0,05 × 10 9 per single unit (buffy coat method)
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Platelets, recovered, pooled, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per pool are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 1 × 10 6 per pool
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Platelets, recovered, single unit
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
Leucocyte content
Less than 0,2 × 10 9 per single unit (platelet-rich plasma method)
Less than 0,05 × 10 9 per single unit (buffy coat method)
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Platelets, recovered, single unit, leucocyte-depleted
Volume
Valid for storage characteristics to maintain product within specifications for pH
Platelet content
Variations in platelet content per single unit are permitted within limits that comply with validated preparation and preservation conditions
Leukocyte content
Less than 1 × 10 6 per unit
pH
Minimum 6,4 corrected for 22 °C, at the end of the shelf life
Plasma, fresh-frozen
Volume
Stated volume +/- 10 %
Factor VIIIc (*)
Average (after freezing and thawing): 70 % or more of the value of the freshly collected plasma unit
Total protein (*)
Not less than 50 g/l
Residual cellular content (*)
Red cells: less than 6,0 × 10 9 /l
Leucocytes: less than 0, 1 × 10 9 /l
Platelets: less than 50 × 10 9 /l
Plasma, fresh-frozen, cryoprecipitate-depleted
Volume
Stated volume: +/- 10 %
Residual cellular content (*)
Red cells: less than 6,0 × 10 9 /l
Leucocytes: less than 0,1 × 10 9 /l
Platelets: less than 50 × 109/l
Cryoprecipitate
Fibrinogen content (*)
Greater than or equal to 140 mg per unit
Factor VIIIc content (*)
Greater than or equal to 70 international units per unit
Granulocytes, apheresis
Volume
Less than 500 ml
Granulocyte content
Greater than 1 × 10 10 granulocytes per unit
( 1 ) OJ L 33, 8.2.2003, p. 30.
( 2 ) OJ L 203, 21.7.1998, p. 14.