Commission Implementing Regulation (EU) 2021/1248 of 29 July 2021 as regards measures on good distribution practice for veterinary medicinal products in accordance with Regulation (EU) 2019/6 of the European Parliament and of the Council (Text with EEA relevance)
Article 14Equipment
In force · version of Aug 19, 2021
1.All equipment with an impact on storage and distribution of veterinary medicinal products shall be designed, located and maintained to a standard suitable for its intended purpose. Planned maintenance shall be in place for key equipment vital to the functionality of the operation.
2.Equipment used to control or to monitor the environment where the veterinary medicinal products are stored shall be subject to calibration at defined intervals based on a risk and reliability assessment.
3.Calibration of equipment shall be traceable to a national or international measurement standard. Appropriate alarm systems shall be in place to provide alerts when there are excursions from pre-defined storage conditions. Alarm levels shall be appropriately set and alarms shall be regularly tested to ensure adequate functionality.
4.Equipment repair, maintenance and calibration operations shall be carried out in such a way that the integrity of the veterinary medicinal products is not compromised.
5.Defective vehicles and equipment shall not be used and shall either be labelled as such or removed from service.
6.Equipment not relevant for the wholesale activities shall not be stored in the area where veterinary medicinal products are stored.
7.Adequate records of repair, maintenance and calibration activities for key equipment, such as cold stores, monitored intruder alarm and access control systems, refrigerators, thermohygrometers, or other temperature and humidity recording devices, air handling units and any equipment used in conjunction with the onward supply chain, shall be made and the results shall be retained.